Product

AVL PA-FID C50™

Portable Flame Ionization Detector

The AVL PA-FID C50TM is a portable FID analyzer for monitoring of total organic carbon (TOC) emissions in the process industry and in laboratories.

AVL PA-FID C50

Global environmental protection initiatives require a drastic reduction of pollutant emissions. According to DIN EN 12619 a Flame Ionization Detector (FID) is a reference method for measurements of volatile TOC (Total Organic Carbon) from combustion power plants. Regular service checks are required for permanently installed analyzers of Continuous Emission Monitoring Systems (CEMS). To perform these tasks, the analyzers have to be portable, robust and lightweight as sample points are often difficult to access. For cost-efficient operation, the consumption of operating gases are as crucial as maintenance requirements, both have to be minimized.

The AVL PA-FID C50TM is a Portable FID analyzer for continuous total organic carbon measurement in the process industry and in laboratories. It is specifically designed for robust and easy operation, especially when sampling points are frequently changed e.g. in QAL 2 and AST (Annual Surveillance Test) applications.

The AVL PA-FID C50 meets the highest design requirements and offers excellent test performance combined with cost-efficient operation.

Flexibility

The compact AVL PA-FID C50 is lightweight, easy to transport and requires a minimum of supply gases (ambient air and H2).

Robustness

Measurements can be performed over a wide range of ambient temperature conditions with a neglectable oxygen cross sensitivity.

Excellent Serviceability

The modular design and easy accessibility of the analyzer support quick maintenance activities by the operator.

Certification

A QAL 1 certification is currently under examination, which will enable the PA-FID C50 to be used for QAL 2 or annual surveillance tests (AST).

The AVL PA-FID C50TM is available as a portable Flame Ionization Detector (FID) with a front panel for local operation and as a 19” rack analyzer without front panel.


Measurements can be performed over a wide range of ambient temperature conditions with a neglectable oxygen cross sensitivity and a minimum of required supply gases. Thanks to the QAL1 certification, the PA-FID C50 can be used in various applications like waste incineration or power plants.

Technical Details  
Measured Component TOC (Total Organic Carbon)
Dimensions (W x D x H) 455 x 405 x 181 mm
Weight 18 kg
Power Supply

100 – 120 VAC, 50/60 Hz

200 – 230 VAC, 50/60 Hz

Power Consumption 500 W
Burner Air Ambient air (via internal catalyst)
Remote Operation Web-interface

 

AVL PA-FID C50 User Interface

DIN EN 15267 
Certified measuring- and evaluating-systems according to EN 15267

QAL 1 (in work)

AVL PA-CLD C50
AVL CLD C50™

The AVL CLD C50™ is a light-weight Chemiluminescence Detector for stand-alone use in indoor areas or as a stack analyzer in emission measurement systems.

PA-FTIR C50
AVL PA-FTIR C50™

The AVL PA-FTIR C50™ is a compact and lightweight FTIR analyer for emission monitoring in the process industry.

AVL FTIR C50
AVL FTIR C50™

The AVL FTIR C50™ is a multi component measuring system for stationary emission monitoring.

AVL iCAL GDU gas divider
AVL iCAL GDU SL™

The AVL iCAL GDU SL™ is a portable gas divider for linearity verification of gas analyzers.